Capsular Tension Rings
PMMA capsular tension rings and segments that stabilise the capsular bag in eyes with weak or missing zonules, supporting safer cataract surgery and long-term IOL centration.
Capsular Tension Rings Products
Explore a curated range of high-quality medical products engineered for precision, reliability, and consistent clinical performance.
3 products available

Capsular Tension Ring – Standard
An open PMMA capsular tension ring with blunt-tipped eyelets, in four sizes from 11 to 14 mm, that stabilises the capsular bag in mild zonular weakness and supports long-term IOL centration.

Capsular Tension Ring – Modified (Scleral Fixation)
A PMMA capsular tension ring with a raised fixation hook on the left, right or both sides for scleral suture fixation, in four sizes from 11 to 14 mm, for moderate to severe or progressive zonular loss.

Capsular Tension Segment
A PMMA partial-ring capsular tension segment with a raised fixation eyelet for scleral suture fixation, giving targeted support to the capsular bag where zonular loss is localised.
Capsular Support for Weak Zonules
Capsular tension rings (CTRs) are open PMMA rings placed in the capsular bag during cataract surgery. They spread outward tension evenly around the bag, transferring support from healthy zonules to weak or missing ones. This helps reduce intraoperative complications, limit capsular contraction and keep the IOL well centred over the long term.
Our Range
Standard CTRs in four sizes (11 to 14 mm open diameter) for mild zonular weakness. Modified CTRs with fixation hooks (left, right or both sides) for scleral suture fixation in more advanced zonular loss. Capsular tension segments for localised zonular defects. All are available in clear or blue PMMA, with blunt-tipped eyelets for safe insertion.
Frequently Asked Questions About Capsular Tension Rings
Common questions about Capsular Tension Rings.
In eyes with weak or partially missing zonules, such as in pseudoexfoliation, trauma or high myopia, to stabilise the capsular bag during and after cataract surgery.
A modified CTR has one or two fixation hooks that let it be sutured to the sclera, for more advanced or progressive zonular loss.
Open diameters of 11, 12, 13 and 14 mm, compressing to 9, 10, 11 and 12 mm in the bag.